Before operation, the Aqua Rite must be co nfigured for the chlorinator cell that will be used. Aqua Rite Salt System; Aqua Plus® Salt System; Aqua Trol Above-ground; Salt & Swim™ 3C; Pentair Salt Systems. Check local codes for other ... Hayward does not recommend using the Aqua Rite to generate bromine. To teach the ID code to the Aqua Pod remote unit: 1 10 LIMITED WARRANTY (effective 01/01/09) Goldline warrants its Aqua Rite, Aqua Rite Pro, Aqua Logic, Pro Logic and E-Command products to be free of defects in materials and workmanship, under normal use and service for a period of three (3) years. 188: VAC input voltage is too low. Pools, Spas and Hot Tubs - Aquarite chlorine generator No Flow lite on - About 5 yr old Aquarite chlorine generator that has always worked great. Replaced GLX-PCB-RITE but nothing shows on display. Salt reading on panel indicates 4.4 versus typical salt range in … sanitization advanced all-in-one aop. I also cleaned the cell and still got a "HOT" reading. 188: VAC input voltage is too low. Please return the board (your expense) for free repair if the repair fails within 12 months. Refer to the Jandy instructions and the wiring diagrams below, and the Aqua Rite® instructions and the wiring diagrams below for proper wiring connection to the Chlorinator Translator. 3200PPM Move to previous/next menu item Salt level of the pool is 3200. Before operation, the Aqua Rite must be configured for the chlorinator cell that will be used. February 25, 2016; Jandy VS Flopro connected to older Jandy systems. CircuPool® CIR-T15 Replacement Cell compatible with Hayward® Aqua Rite® Turbo T-Cell-15 (T-15) $589.00 $499.00 Sale. Display shows all settings but salt is zero. Get support by contacting us online Contact Support. Used with t-15 turbo cell. See more ideas about swimming pool cleaning, swimming pool maintenance, pool cleaning. This circuit board is easily installed into your existing control unit. My new Aqua-Rite is not producing chlorine. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in … Recently the no … Try turning off the system and unplug the PCB board from the unit and then reseat the board on the pins. • Equipment can be programmed to run off daily schedules and/or based on manual commands. Page 3 Check System Light On: 1. Also, I found it strange that I had to go to the WEB to find our what the correct operating volt and amperage ranges are since the manual that came with the system failed to include them. Mar 10, 2021 - Swimming pool cleaning and maintenance guide to chemicals for your swimming pool and swimming pool cleaning equipment to keep your pool clean, sparkly and blue. 10 year old Hayward Progrid DE filter May 27, 2016; Quick and Easy Filter replacement. There can be many events which may on to the next menu item to "lock in" your new setting. View Details Add To Cart. In Stock. Product Details » Universal ColorLogic Pool & Spa Lights June 9, 2012 This warranty Any help in diagnosing this issue would be greatly appreciated. system. Hello. Saltwater Swimming Pools Overview. This is measured by the Goldline Aqua Rite or Hayward Swimpure when external chlorination is used. Shop Hayward Residential and Commercial Pool Products online. The board pictured will not be sent to you.) Page 4 Before operation, the Aqua Rite must be configured for the chlorinator cell that will be used. IntelliChlor Salt Chlorinator; Zodiac Salt Water Systems. “t-15” is the factory default. To the left is an explanation of The 6th -8th number will be the year & month. My Gold line Aqua Rite cell current drops off after about 10 minutes. The manual that came with this Aqua Rite Pro is very limited with troubleshooting tips. #swimmingpoolmaintenanceguide #swimmingpoolcleaning. • The panel features an 8 slot, 100amp subpanel. Any suggestions After going through all the steps, water, salt, cleaning filters, cleaning cells, having the system reinstalled(on Hayward Tech recommendation) it still does not produce chlorine. Hayward Aqua Rite GLX-PCB-RITE Main PCB Printed Circuit Board for the Hayward T-Cell Control Box. Hayward Aqua rite Goldline Salt Generator control panel question/problem. View or download the BROCHURE for the Hayward Aqua Rite. How do you fix this? AquaPure Salt System; AquaPure Ei Series; AquaPure Power Pack; ComPool Salt System; SPA LIGHTS. Any ideas? Cell tested good at Pool store. "pcb" code on aqua rite control panel Post by Guest » Wed 12 Aug, 2009 09:09 The current limiter Inrush located in the top right corner of the pcb is the problem I had. Contact Hayward Support We are here to help with all of your Hayward Pool Products. The SL32 2R025 is a NTC Thermistor with radial leads. 189: Relay not conducting in the forward direction. It has a chlorine production capacity of 0.53 lbs per day. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. I talked to goldline and they said there was a board problem cause it says, “cell power error” I can turn the whole system off and turn back on and it will be ok for a day or two, then it comes back. Check out the Sundance® Spas Flow Switch Replacement if you are looking for the flow switch replacement for your Sundance® Spa / Jacuzzi® Generic Flow Switch for Hayward®/Goldline® Salt Systems Features: Generic Replacement for: All Hayward®/Goldline® flow switches: Hayward®/Goldline® Aqua Logic®, AquaPlus®, AquaRite®, AquaRite Pro®, AquaRite XL®, Blue … ‘No Cell Power’ means the current chlorinator cycle has been interrupted due to no voltage being detected when the cell power relay was turned on. If the incorrect cell is chosen the salt level, amperage, and voltage will not be correct and the system will turn the chlorinator off. Soldering the current limiter on the Aqua Rite PCB. Kurt The smallest in-ground pool system in the Aqua Rite range of pool sanitizers by Hayward, this particular system supports a pool capacity of up to 15,000 gallons. This will sometimes fix strange issues with the PCB board as some of the contacts might not be making a good connection. (This auction is for a REPAIR to your Aqua Rite, NatureSoft, Mineral Springs, SmartPure, AquaLogic , Hayward, Goldline or ProLogic GLX-PCB-RITE System board that you mail to me. How To Read Serial Number & Date Codes Heat Pumps, Heaters*, Filters, Pumps 2005 & Forward (21) 120-402-000002006 Pictured above is the new Hayward ID Tag that will replace our current serial number system. • These systems can manage: Hayward Variable Speed Pumps, ColorLogic Lighting, Sense & Dispense, AquaConnect Homenet, as well as a wide variety of remotes. "IF" - Hayward Pool Heater Fails to Ignite: the most common reason for this problem is insufficient gas supply. “t-15” is the factory default.If the incorrect cell is chosen the salt level, amperage, and voltage will not be correct and the system will turn the chlorinator off. CENTER. The cell current starts out a little low, around 4.25, with the cell voltage good. Hayward Salt Systems. Hi Everyone, I've had my aquarite a few years now but recently I got a "Hot" reading and checked the temp and it read 184F. Hayward Pool Products View FAQs. There are no red LED lights on, and the green generating light is still illuminated. This display will be shown only if external chlorination is used and requires a Aqua Rite or Swimpure chlorine generator. Re-installed old board and it light up and shows all the codes. (Generates 173 – Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. Hayward Spa Lights. (Generates 173 code if Level II code 187 is present) Contact a pool professional. Lead Spacing 0.307" (7.80mm). The PCB board tells the cell to generate at a specific chlorine percentage, as long as it meets a specific set of parameters (salt level, water temp, water flow, ex). Slide the Main Switch to the “Auto” position. It is specially designed to withstand up to 25A of continuous current and 300J of input energy. (Generates 173 code if Level II code 187 is … (Generates 173 - Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. Repairing My Aqua Rite PCB (GLX-PCB-RITE) that was Damaged by … GLX-PCB-MAIN. sp740DE makes it happen May 13, 2016; No Flow problem Solved May 3, 2016; New Hayward Heater, Filter and Valve. No Cell Power 1 or No Cell Power 2 No Cell Power 1 sanitization. Limited 12 month Guarantee! Leslies black filter to Hayward Progrid. Hayward Goldline AquaRite Salt Chlorination System stopped making chlorine. When it … I noted on the diagnostic that the amperage reading was running about 3.21 to 3.45 which is lower than what is the proper operating level. The Aqua-rite system is just a terrible system.I have spent 10 months trying to get a consistently functioning system. This can't be as the water should be around 65F. LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years. View or download the MANUAL for the Hayward Aqua Rite. The Hayward heater LED display will show a diagnostic fault code of "IF" which stands for Ignition Failure.Undetected gas pressure problems if not investigated properly may result in unnecessary replacement and servicing of your Hayward Pool Heater. If the incorrect cell is chosen the salt level, amperage, and voltage will not be correct and the system will turn the chlorinator off. Country of … Page 31: Warranty Ecommand 4 Warranty Covid-19 & Pools COVID-19 RESOURCE. Front board power supply either too low or too high. After about 10 minutes, the cell current drops to 0, and the cell voltage rises to around 30. learn more. “t-15” is the factory default. Hayward's AquaRite Salt Chlorinator is the convenient alternative to conventional chlorine - bringing your pool the very best. Equipment such as heaters can be programed to How To Set Turbo Cell Type To switch Cell Type, cycle Main Switch from AUTO Super Chlorinate AUTO. Soldering the current limiter on the Aqua Rite PCB.